Evaluating Activated Carbons

May 28, 2002
The American Society for Testing Methods (ASTM) and American Water Works Association (AWWA) have standard test methods for commerce between buyers and sellers of activated carbons (AC). These methods have been discussed in other articles 1,2 and are listed in Table 1 by title and method number. The methods are used for purchasing and monitoring after the AC is installed. New challenges are emerging in the industry that require new methods and product developments. This article discusses additional test methods for the AC industry.

The American Society for Testing Methods (ASTM) and American Water Works Association (AWWA) have standard test methods for commerce between buyers and sellers of activated carbons (AC). These methods have been discussed in other articles 1,2 and are listed in Table 1 by title and method number. The methods are used for purchasing and monitoring after the AC is installed. New challenges are emerging in the industry that require new methods and product developments. This article discusses additional test methods for the AC industry.

Blending GAC Lots

All ACs are not equal. It is common practice to blend different lots of AC with different standard method iodine number values to meet the customer specifications. Often in drinking water applications, used granular activated carbon (GAC) from drinking water adsorbers is furnace reactivated to provide a resource for additional use cycles. Only dedicated furnaces for regeneration of used GAC from water filters can be used when the GAC will be returned to drinking water filtration. Since each cycle of the reactivation process loses abut 10 percent of the original GAC volume, unused make-up GAC must be added to the reactivated lot to get the original volume to fill the customers adsorber.

New test methods are needed to detect blended lots of GAC. The ASTM iodine number is an average of the blended lot, thus 50:50 blend of 1,000 and 700 iodine numbers yields a 850 iodine number. This heterogeneous lot (1,000:700) meets the 850 client specification but will have significantly different performance compared to a homogenous 850. The authors are developing new methods to detect heterogeneous GAC (granule-to-granule for intergranule heterogeneity and intragranule, outside granule versus inside granule heterogeneity). Currently, the AC industry does not have test methods for heterogeneity determination; presently, average and index values are provided.

GAC granules from blended lots can be separated based on apparent specific gravity test methods. Once the granules are separated they can be tested with standard AWWA, ASTM or heat-of-immersion test methods under development, commonly referred to as the AC Tester, which is the method PACS and ASTM’s method development group committee D-19 are developing. The external portion of the separated granules can be removed by using a gem polisher. Once the exterior is worn off, the dust can be separated by using standard U.S. sieves. The gem polisher also can be used to remove coatings from other media. Again, the separated portions, exterior and interior granule parts, can be tested with standard AWWA or ASTM methods or the AC Tester.

The AC Tester results should be used by a professional who has knowledge about the specific adsorption systems being studied. The decision when the carbon is exhausted and needs replaced is a site-specific decision process. It depends on the toxicity of the adsorbates, competition of adsorbates and possibly moisture effects on the adsorption capacity.

AC Tester—Remaining AC Service Life

Two common questions concerning GAC installations are “How good is this GAC?” and “How long can I use this GAC before it needs to be changed?” The first question partially is answered using ASTM methods listed in Table 1, before purchase and installation. The second question is more difficult because there are no standard methods for testing used GAC to estimate remaining service. The authors have been working on a method to answer this important question and they have come up with a simple and low-cost test device called the AC Tester. This method is based on the concept that as the adsorption space in GAC fills, less heat is given off when adsorptive materials challenge it. In an initial space distribution in a bed of GAC, 40 percent of the volume is inside the GAC granules. Thus the AC Tester determines the heat rise of the unused GAC to compare with an equal volume of the used GAC. Rationing the temperature rises gives an estimate of the adsorption volume used (i.e., 4° C rise for unused and 1° C rise for used indicates only 50 percent of the original adsorption space is occupied.) Thus this example suggests adsorption space still remains in this used GAC, but the operators need to proceed with caution.

EPA Toxicity Characteristic Leaching Procedure

The EPA toxicity characteristic leaching procedure (TCLP) is a third-generation regulatory test method to determine if a waste material has potential to contaminate groundwater. This method consists of leaching used GAC with a simulated landfill aqueous acetate solution. The water extracted GAC adsorbates are analyzed for a target list of organic and inorganic toxic compounds. The 10 highest concentrations of organics and metals in the extracts in addition to the target list are qualitatively and quantitatively determined. Experience using the TCLP on used AC has shown the adsorbed organics have a negligible recovery using TCLP, but metals often are recovered. These recoveries are reasonable because the carbon adsorbed were accumulated from water passing through carbon. The high energy binding sites in the carbon hold on to adsorbates strongly and are not detached by buffered acetate solutions. California has a more aggressive extraction method based on using citric acid to evaluate a materials potential to leach and contaminate the ground water.

The authors have reported on liquid cocktails that can recover organics from used GAC.3,4 These extracting liquids were developed for a new commercial regeneration process, “Liquid Regeneration of Commercial Used GAC,” and found to be very efficient.4 A version of this kicker/chase solvent for used GAC adsorbate recovery and analysis is under development as a stream monitor.5

Presently, there needs to be a test method capable of detecting 10-9 to 10-12 molar organics in water. The pharmaceutical food and specialty chemical industry have the potential of adding these concentrations to public waters. Some of these compounds are suspected to have endocrine disrupter and other deleterious biological effects.6 GAC can enrich water organics 10,000–100,000 fold, which is the basis of this new stream monitor method.          

Acknowledgement

The authors thank Professor Emeritus Dr. Milton Manes for regularly sharing his thoughts about new opportunities in the AC industry. He is the originator of the kicker/chaser concept and many other innovations presently used in the AC industry. Manes has provided a short course for 12 years titled, “AC Adsorption: Principles and Applications,” for PACS and the American Chemical Society.

About The Author:

Henry G. Nowicki, Ph.D. and MBA, directs the PACS Laboratory testing and consulting services and new business developments at PACS. He has obtained three patents and published more than 100 articles about environmental issues and AC ads

Sponsored Recommendations

The Science Behind Sustainable Concrete Sealing Solutions

Extend the lifespan and durability of any concrete. PoreShield is a USDA BioPreferred product and is approved for residential, commercial, and industrial use. It works great above...

Powerful Concrete Protection For ANY Application

PoreShield protects concrete surfaces from water, deicing salts, oil and grease stains, and weather extremes. It's just as effective on major interstates as it is on backyard ...

Concrete Protection That’s Easy on the Environment and Tough to Beat

PoreShield's concrete penetration capabilities go just as deep as our American roots. PoreShield is a plant-based, eco-friendly alternative to solvent-based concrete sealers.

Proven Concrete Protection That’s Safe & Sustainable

Real-life DOT field tests and university researchers have found that PoreShieldTM lasts for 10+ years and extends the life of concrete.