|
|
 |
 |
 | EDITORIAL CATEGORY - PUMPING |
|
|
Prefab Pump Station Proves Worth
Water & Wastes Digest
April 2004
By Clifford Seth
“We couldn’t put all we needed above ground because the expense was prohibitive, and the prefabricated option for the pump station provided the reliability we wanted for the underground addition.”
Pump Up the Volume
Water & Wastes Digest
October 2003
G. Michael Strombach
The Grand Coulee Dam releases, on average, 110,000 cubic feet of water per second, primarily for generating electricity. Controlling huge volumes of water requires giant-sized equipment, which can sometimes face giant-sized problems when problems occur. Three of the 24 turbines are rated at 805 megawatts and are some of largest turbines ever built. Making sure they consistently function in a reliable manner can present significant hurdles for maintenance engineers and mechanics.
How Grease-Lubricated Bearings Function
Pump Source
April 2003
A shielded, grease-lubricated ball bearing can be compared to a centrifugal pump having the ball-and-cage assembly as its impeller and the annulus between the stationary shield and the rotating inner race as the eye of the pump. Shielded bearings are not sealed bearings.
Intermittent Seal Leak in LPG Pump
Pump Source
April 2003
Sourav Kumar Chatterjee
The following case study describes a reliability problem with a Liquified Petroleum Gas (LPG) handling pump in a field and the way it was troubleshooted and fixed.
Heavy Duty Drainage Pumps Rescue Stormwater Flooded Quarry
Water & Wastes Digest
February 2003
Pumping around the clock at 10,000 gpm, two 94hp submersible, portable dewatering pumps manufactured by Pumpex, Inc. of Somerville, N.J., drained turbulent, overflowing stormwater to save a limestone quarry from extensive equipment damages and potential profit loss caused by severe flooding.
Metering Pump Technology
Water Quality Products
March 2002
By Steven Ebersohl, Pulsafeeder, Inc.
Since the introduction of the metering pump, chemical feed for disinfection has been a primary application. As we move into the 21st Century, it again is time to review how we introduce chemicals such as sodium hypochlorite into our water systems. While the goal remains the same, changes in pump technology have been created to provide more accurate and consistent results. This article will discuss current metering pump technologies, proper pump sizing, installation and future enhancements.
Production of High Purity Water From Seawater
Water Quality Products
March 2002
Contributed by Ted Prato, Erik Schoepke, Lance Etchison, Tom O’Brien, Brian Hernon and Kit Perry, I
The Diablo Canyon Power Plant at Avila Beach in California utilizes seawater for both cooling water and makeup water for steam generation. Ionics, Inc., Watertown, Mass., designed and built and now operates a complete water treatment system serving the high-purity water needs of this power plant. Over the past eight years, the seawater treatment section has demonstrated excellent long-term performance as a result of strong design, consistent maintenance and qualified operators.
Problem Solver: Godwin Pump
Water & Wastes Digest
September 2001
Innovative Pumping System Diverts 75 mgd Sewer Flow During Rehab Project In Puerto Rico
Pumping Up Big John
Water Quality Products
April 2001
Metropolitan Industries
The John Hancock building, located on Chicago’s Magnificent Mile, needed to revamp its entire pumping and reservoir system without shutting off water to the building’s residents.
PDF Version
Updated Sewage System Gives Tourists a Lift
Water Engineering & Management
September 2000
Cecil Coombs, P.E.
Sewage overflow caused by the influx of visitors during tourist season prompted one community to improve its collection and treatment system.
From Eyesore to State-of-the-Art Facility: Pump Station Transformation
Water Engineering & Management
August 2000
Roger Frauenfelder, P.E.
What was formerly a contaminated auto wrecking yard that twice caught fire and was an eyesore to the local community is being transformed into a state-of-the-art pump station. This transformation not only resolves critical infrastructure needs but also is aesthetically pleasing.
Company Rehabs Trunk Sewer While Rerouting 12 mgd of Sewage Flow
Water Engineering & Management
July 2000
Using a temporary sewage bypass pumping system and its nondisruptive pipe rehabilitation methods, Insituform Technologies, Inc., has rehabilitated a half-mile-long section of trunk sewer buried beneath a Tucson roadway.
New Ductile Iron Check Valve Stops Water Hammer In Louisiana Municipality
Water & Wastes Digest
August 1999
After suffering years of water hammer problems and the resulting effect on maintenance personnel and equipment, the St. Charles Parish Municipality in Louisiana needed a product that would save them both time and money. Milliken Valve Company of Bethlehem, Pa., provided the answer.
Selection Criteria for Wastewater Pumps Part 3
Water Engineering & Management
November 1998
Bayard Bosserman, P.E. and Paul Behnke, P.E.
This article summarizes the criteria for selecting pumps for specific wastewater applications.
Selection Criteria for Wastewater Pumps (Part 2)
Water Engineering & Management
October 1998
Bayard Bosserman, P.E. and Paul Behnke, P.E.
The second part of this article compares the different types of pumping stations available to the wastewater industry.
Selection Criteria for Wastewater Pumps
Water Engineering & Management
September 1998
Bayard Bosserman, P.E. and Paul Behnke, P.E.
Part 1 of this article discusses the types of wastewater pumps available and the need for screens.
|
|
|
 |
|
|
|